We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate within our success for 2019 China New Design 10/35kv Copper Conductor Power Cable/Marine, For more details, please get hold of us as soon as possible!
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate within our success for China XLPE Power Cable and Underground Cable, With the goal of “zero defect”. To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
Conductor: | Soft annealed bare copper wire |
Conductor size: | 23 AWG |
Insulation: | PE-Foam |
Insulation OD: | Normal Ø1.38 ± 0.05 mm |
Insulation thickness | 0.39 mm |
Pair: | 2 insulated conductors stranded together into a pair |
Color code: | 1. White/blue + Blue 2. White/orange + Orange 3. White/green + Green 4. White/brown + Brown |
Shield pair to pair: | Aluminum Foil-Polyester Tape |
Shield pair to pair coverage: | 100% |
Outer shield: | Solid Tinned Copper Braid |
Outer shield coverage: | Nom 80% |
Outer jacket: | LSZH SHF1 |
Nominal outer sheath thickness: | 0.75 ± 0.30 mm |
Outer jacket OD: | 8.4 ± 0.50 mm |
Marking: | YANGER® CAT7A 4x2x23/1 AWG Solid S/FTP LSZH-SHF1 <batch no.> <meter marking> |
Outer jacket color: | Grey |
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate within our success for 2019 China New Design 10/35kv Copper Conductor Power Cable/Marine, For more details, please get hold of us as soon as possible!
2019 China New Design China XLPE Power Cable and Underground Cable, With the goal of “zero defect”. To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
Degree of acidity of gases: | IEC 60754-1/2 |
Halogen acid gas: | IEC 60754-1/2 |
Smoke emission: | IEC 61034-1/2 |
Flame retardant: | IEC 60332-1-2 |
UV resistance | UL 1581 |
Fire retardant: | IEC 60332-3-22 |
Resistance of the conductor@20°C: | ≤93.8 Ω/km |
Insulation resistance: | ≥5000 MΩ/km |
Average characteristic impedance @100 MHz: | 100 ± 5 Ω |
Transfer impedance: | ≤100 mΩ/m @10 MHz |
Delay skew (4~100 MHz): | ≤25 ns/100 m |
Velocity factor: | 74% |
Conductor resistance unbalance within pair: | ≤2.0% |
Conductor resistance unbalance between pair: | ≤4.0% |
capacitance unbalance to earth at 800Hz or 1000Hz: | ≤160 pF/100 m |
Mutual capacitance: | ≤56 nF/km |
Frequency (MHz): | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 | 200 | 250 | 300 | 500 | 600 | 1000 |
Attenuation dB/100m (Max.) | - | 3.7 | 5.8 | 7.3 | 8.2 | 10.3 | 14.6 | 18.5 | 26.5 | 29.7 | 32.7 | 42.8 | 47.1 | 61.9 |
NEXT dB (Min.) | 78 | 78 | 78 | 78 | 78 | 78 | 78 | 75.4 | 70.9 | 69.4 | 68.2 | 64.9 | 63.7 | 60.4 |
PS-NEXT (Min.) | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 72.4 | 67.9 | 66.4 | 65.2 | 61.9 | 60.7 | 57.4 |
Return Loss dB (Min.) | 20 | 23 | 25 | 25 | 25 | 23.6 | 21.5 | 20.1 | 18 | 17.3 | 17.3 | 17.3 | 17.3 | 15.1 |