To create far more benefit for customers is our company philosophy; customer growing is our working chase for Manufacturer of 12/20kv 95mm Marine Shipboard Cable Electric Power Cable, How about to start your good organization with our corporation? We are all set, properly trained and fulfilled with pride. Let’s start our new business enterprise with new wave.
To create far more benefit for customers is our company philosophy; customer growing is our working chase for China Electric Cable and Power Cable, Being the top solutions of our factory, our solutions series have been tested and won us experienced authority certifications. For additional parameters and item list details, make sure you click the button to acquire additional nformation.
Conductor: | Soft annealed bare copper wire |
Conductor size: | 23 AWG |
Insulation: | PE-Foam |
Insulation OD: | Normal Ø1.38 ± 0.05 mm |
Insulation thickness | 0.39 mm |
Pair: | 2 insulated conductors stranded together into a pair |
Color code: | 1. White/blue + Blue 2. White/orange + Orange 3. White/green + Green 4. White/brown + Brown |
Shield pair to pair: | Aluminum Foil-Polyester Tape |
Shield pair to pair coverage: | 100% |
Outer shield: | Solid Tinned Copper Braid |
Outer shield coverage: | Nom 80% |
Outer jacket: | LSZH SHF1 |
Nominal outer sheath thickness: | 0.75 ± 0.30 mm |
Outer jacket OD: | 8.4 ± 0.50 mm |
Marking: | YANGER® CAT7A 4x2x23/1 AWG Solid S/FTP LSZH-SHF1 <batch no.> <meter marking> |
Outer jacket color: | Grey |
To create far more benefit for customers is our company philosophy; customer growing is our working chase for Manufacturer of 12/20kv 95mm Marine Shipboard Cable Electric Power Cable, How about to start your good organization with our corporation? We are all set, properly trained and fulfilled with pride. Let’s start our new business enterprise with new wave.
Manufacturer of China Electric Cable and Power Cable, Being the top solutions of our factory, our solutions series have been tested and won us experienced authority certifications. For additional parameters and item list details, make sure you click the button to acquire additional nformation.
Degree of acidity of gases: | IEC 60754-1/2 |
Halogen acid gas: | IEC 60754-1/2 |
Smoke emission: | IEC 61034-1/2 |
Flame retardant: | IEC 60332-1-2 |
UV resistance | UL 1581 |
Fire retardant: | IEC 60332-3-22 |
Resistance of the conductor@20°C: | ≤93.8 Ω/km |
Insulation resistance: | ≥5000 MΩ/km |
Average characteristic impedance @100 MHz: | 100 ± 5 Ω |
Transfer impedance: | ≤100 mΩ/m @10 MHz |
Delay skew (4~100 MHz): | ≤25 ns/100 m |
Velocity factor: | 74% |
Conductor resistance unbalance within pair: | ≤2.0% |
Conductor resistance unbalance between pair: | ≤4.0% |
capacitance unbalance to earth at 800Hz or 1000Hz: | ≤160 pF/100 m |
Mutual capacitance: | ≤56 nF/km |
Frequency (MHz): | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 | 200 | 250 | 300 | 500 | 600 | 1000 |
Attenuation dB/100m (Max.) | - | 3.7 | 5.8 | 7.3 | 8.2 | 10.3 | 14.6 | 18.5 | 26.5 | 29.7 | 32.7 | 42.8 | 47.1 | 61.9 |
NEXT dB (Min.) | 78 | 78 | 78 | 78 | 78 | 78 | 78 | 75.4 | 70.9 | 69.4 | 68.2 | 64.9 | 63.7 | 60.4 |
PS-NEXT (Min.) | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 72.4 | 67.9 | 66.4 | 65.2 | 61.9 | 60.7 | 57.4 |
Return Loss dB (Min.) | 20 | 23 | 25 | 25 | 25 | 23.6 | 21.5 | 20.1 | 18 | 17.3 | 17.3 | 17.3 | 17.3 | 15.1 |