High reputation Rg8X LMR240 50ohm Coaxial Cable RF SMA Low Loss in Marine Antenna System

Short Description:

For used in power transmission and distribution system, suitable for outdoor use at temperature range
from -52℃ to +80℃.


  • Application: For used in power transmission and distribution system, suitable for outdoor use at temperature range from -52℃ to +80℃.
  • Standard & specification: Cable design comply with IEC 60502-1, IEC 60228, GOST 31996- 2012, GOST 22483-2012, IEC 60332-3-22, IEC 60331, IEC 61034, IEC 60754-2, GOST 31565-2012
  • RFQ

    Product Detail

    Design

    Cable marking-Inkjet

    Operation condition

    Product Tags

    We depend on sturdy technical force and continually create sophisticated technologies to fulfill the demand of High reputation Rg8X LMR240 50ohm Coaxial Cable RF SMA Low Loss in Marine Antenna System, With our rules of ” business reputation, partner trust and mutual benefit”, welcome all of you to work together , grow together.
    We depend on sturdy technical force and continually create sophisticated technologies to fulfill the demand of China Coaxial Cable RF and Rg8X, Our company has already have pass the ISO standard and we’re fully respect our customer ‘s patents and copyrights. If the customer provides their own designs, We will guarantee that they might be the only one can have that merchandise. We hoping that with our good items can bring our customers a great fortune.
    For used in power transmission and distribution system, suitable for outdoor use at temperature range
    from -52℃ to +80℃.

    We depend on sturdy technical force and continually create sophisticated technologies to fulfill the demand of High reputation Rg8X LMR240 50ohm Coaxial Cable RF SMA Low Loss in Marine Antenna System, With our rules of ” business reputation, partner trust and mutual benefit”, welcome all of you to work together , grow together.
    High reputation China Coaxial Cable RF and Rg8X, Our company has already have pass the ISO standard and we’re fully respect our customer ‘s patents and copyrights. If the customer provides their own designs, We will guarantee that they might be the only one can have that merchandise. We hoping that with our good items can bring our customers a great fortune.


  • Previous:
  • Next:

  • 3.1 Conductor
    Up to 2.5mm²: Tinned annealed stranded circular non-compacted
    copper conductor in accordance with IEC 60228 Class 2
    4 to 25mm²: Plain annealed stranded circular non-compacted
    copper conductor in accordance with IEC 60228 Class 2
    Above 25mm²: Plain annealed stranded circular compacted copper
    conductor in accordance with IEC 60228 Class 2
    3.2 Fire proof layer
    Mica Glass tape overlapped around the conductor
    3.3 Insulation
    Extruded XLPE compound comply with IEC 60502-1
    Color:
    2C: Brown, Blue
    3C: Black, Brown, Grey
    4C: Black, Brown, Grey, Blue
    2C+E: Brown, Blue, Green/Yellow (Earth)
    3C+E: Black, Brown, Grey, Green/Yellow (Earth)
    4C+E: Black, Brown, Grey, Blue, Green/Yellow (Earth)
    5 core and above: black core printed white numbers
    3.4 Assembly and filler(optional)
    The interstices between cores filled with non-hygroscopic
    polypropylene rope to form substantially circular shape with a
    suitable binder tape
    3.5 Inner sheath
    Extruded LSZH ST8 compound comply with IEC 60502-1
    Color: Black
    3.6 Metal amour
    A layer of galvanize steel wires with suitable binder tape helically applied on the inner sheath

    3.7 Outer sheath
    Extruded LSZH ST8 compound comply with IEC 60502-1
    Color: Orange with a red strip

    For example:
    EAC YANGER IEC 60331 CU/MGT/XLPE/LSZH/SWA/LSZH 2C×2.5+E 2.5 SQMM 0.6/1kV нг (А) – FRHF -52°
    C~+40°C YEAR ****M
    Note: “****M” meter marking by inkjet with increased sequence with numbering
    “нг (А) – FRHF” at least every 1 metre appear on the cable

    Rated voltage, U0/U(Um), kV 0.6/1(1.2)
    Rated, operating temperature range, ℃ -52~+80
    Min. installation temperature without preheating, ℃ -20
    Max. conductor temperature in service, ℃ 90
    Max. permissible short-circuit temperature,5 sec, ℃ 250
    Min. bending radius, D overall diameter of cable 12D
    Flame retardant IEC 60332-3-22
    Fire resistant IEC60331(2 h)
    Halogen Gas Emission IEC 60754-1, < 0.5%
    Low Smoke Emission IEC 61034-1/2
    UV resistant UL 1581
    Oil resistant IEC60811(IRM 902 – 4h at 70°C, variation ±40%)
    Oxygen Index(Sheath) ASTM D 2863
    Cold bend IEC 60811-1-4, -35℃
    Cold impact IEC 60811-1-4 & CSA C22.2 No.38-10, -35℃
    Chemical resistance Accidental

     

  • Write your message here and send it to us