Our growth depends around the superior machines, exceptional talents and consistently strengthened technology forces for Super Purchasing for UL2919 PVC Insulated Low Voltage Multicore Cable and Wire Harness for Marine Instrument, We play a leading role in delivering shoppers with premium quality goods great assistance and competitive rates.
Our growth depends around the superior machines, exceptional talents and consistently strengthened technology forces for China Flexible Cable and Power Cable, We follow up the career and aspiration of our elder generation, and we have been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Overview
Calibration gas mainly used in the calibration and detection of petrochemical process control instruments, the quality control of petrochemical products, environmental pollutant detection, exhaust emission detection of automobile and ships, the detection of various factory exhaust gases, the calibration of mine alarms, and the calibration of medical instruments inspection, power system transformer oil quality inspection, air separation product quality control, traffic safety inspection instrument calibration, geological prospecting and seismic monitoring, metallurgical analysis, gas appliance experiment and calorific value analysis, chemical fertilizer industry instrument calibration, etc.
Note:
● The bottled gas product is a high-pressure filling gas, and it should be used after decompression and depressurization.
● The packaged gas cylinders have a service life limit, and all expired gas cylinders must be sent to a department for safety inspection before they can be used. When exhaust gas is used in each bottle of gas, the residual pressure in the bottle should be kept at 0.5MPa-0.25MPa, and the bottle valve should be closed to ensure gas quality and safety in use.
● Bottled gas products should be sorted and stocked during transportation, storage and use. Combustible gas and combustion-supporting gas should not be stocked together, and should not be near open flames and heat sources, and should be kept away from fire, oil wax, exposure to the sun, or re-throwing. Don’t hit, it is strictly forbidden to start arc on the gas cylinder, and it is strictly forbidden to load and unload savagely.
Advantages
● Accuracy: Free large-scale R&D bases and production and processing sites with reliable value brands
● Stability: high stability of national metrological standard gas
Reliable: establish and operate a comprehensive quality management system for label gas development, production, sales and technical services in stric
Specification
Gas Components |
Volume/L |
CO2:8%,SO2:160PPM,N2,100ba |
4 |
8 |
|
NO:0.2%,N2,100bar |
4 |
8 |
|
CO2:5.5%, SO2:27ppm,N2,100bar |
4 |
8 |
|
CO2:22.5%,SO2:1800ppm,N2,100bar |
4 |
8 |
|
High Purity Nitrogen (99.999%) |
4 |
8 |
|
Pressure Reducing Valve |
1 |
Our growth depends around the superior machines, exceptional talents and consistently strengthened technology forces for Super Purchasing for UL2919 PVC Insulated Low Voltage Multicore Cable and Wire Harness for Marine Instrument, We play a leading role in delivering shoppers with premium quality goods great assistance and competitive rates.
Super Purchasing for China Flexible Cable and Power Cable, We follow up the career and aspiration of our elder generation, and we have been eager to open up a new prospect in this field, We insist on “Integrity, Profession, Win-win Cooperation”, because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
Temperature Range: | -40°C~70°C |
Halogen acid gas, Degree of acidity of gases: | IEC 60754-1/2 |
Jacket, Insulation material: | IEC 60092-360 |
Smoke Emission: | IEC 61034-1/2 |
Flame Retardant: | IEC 60332-3-22 |
UV-resistant: | UL 1581 |
Conductor resistance: | ≤ 1.6 Ω /km |
Screen resistance: | ≤ 2.4 Ω /km |
Inductance: | 0.19 [μH/m] |
Peak RF voltage: | 1.8 KV |
Peak power rating: | 32 KW |
Insulation resistance: | 10G Ω/km |
Capacity: | 76 pF/m |
Impedance: | 50 ± 2 Ω |
Velocity factor: | 88% |
Min. bending radius: | 60 mm |
Frequency [MHz] | Nominal attenuation [dB/100m] max.105% | Power rating [kW] |
30 | 1.66 | 6.9 |
50 | 2.01 | 5.3 |
88 | 2.51 | 4.0 |
100 | 2.65 | 3.7 |
200 | 3.58 | 2.6 |
300 | 4.31 | 2.1 |
400 | 4.93 | 1.8 |
450 | 5.10 | 1.7 |
500 | 5.49 | 1.6 |
700 | 6.48 | 1.3 |
800 | 7.10 | 1.3 |
900 | 7.30 | 1.3 |
1000 | 7.78 | 1.1 |
1400 | 9.24 | 0.9 |
1800 | 10.90 | 0.8 |
2000 | 11.50 | 0.8 |
2400 | 12.90 | 0.7 |
3000 | 14.50 | 0.6 |
3400 | 15.50 | 0.5 |
6000 | 21.5 | 0.39 |
8000 | 27 | 0.31 |