Izitolo Zefekthri Siemens Lwl Sienopyr Marine Cable Fiber Optic Cable (yokubeka emikhunjini) kanye ne-Offshore Unit 6xv1830-0nh10 Marine Cable Fiber Optic Cable
“Ubuqotho, Ukusungula, Ukuqina, kanye Nokuphumelela” kuwumbono oqhubekayo wenkampani yethu isikhathi eside ukuze yakhe ngokuhlanganyela nabathengi ukuze babuyisane futhi bathole umvuzo ofanayo we-Factory Outlets Siemens Lwl Sienopyr Marine Cable Fiber Optic Cable (yokubeka emikhunjini) kanye ne-Offshore Unit 30-601 I-Offshore Unit 30-001 Fiber Optic Cable wamukelekile abathengi abasekhaya nabaphesheya kwezilwandle ukuze basithinte futhi basebenzisane nathi ukuze ujabulele ikusasa elingcono.
"Ubuqotho, Ukuqamba Okusha, Ukuqina, kanye Nempumelelo" umbono ophikelelayo wenkampani yethu isikhathi eside ukuze wakhe ngokuhlanganyela nabathengi ukuze babuyisane futhi bathole umvuzo ofanayoI-China Industrial Ethernet FC Tp Standard Cable ne-Standard Cable, Abasebenzi bethu babambelela emoyeni “wokusekela Ubuqotho kanye Nokuthuthukiswa Okusebenzisanayo”, kanye nemfundiso “Yekhwalithi Yezinga Lokuqala Ngesevisi Enhle Kakhulu”.Ngokwezidingo zawo wonke amakhasimende, sinikezela ngezinsizakalo ezenziwe ngezifiso nangokwezifiso ukuze sisize amakhasimende afinyelele izinjongo zawo ngempumelelo.Siyakwamukela amaklayenti asekhaya nakwamanye amazwe ukuze ushayele futhi ubuze!
Umqhubi: | I-stranded Bare copper wire |
Usayizi wekhondatha: | 23 AWG |
I-Insulation: | I-PE-Foam/isikhumba-PE |
I-Insulation OD: | Okujwayelekile Ø1.41 ± 0.05 mm |
Ukuqina kwe-insulation | 0.39 mm |
Bhangqa: | Amakhondaktha angu-2 avaleleke ndawonye aba yipheya |
Ikhodi yombala: | 1. Okumhlophe/okuluhlaza okwesibhakabhaka + Okuluhlaza okwesibhakabhaka 2. Mhlophe/owolintshi + Owolintshi 3. Mhlophe/oluhlaza + Okuhlaza 4. Mhlophe/onsuqu + Nsundu |
Ukubhanqa kweShield ukubhanqa: | I-Aluminium Foil-Polyester Tape |
Ukubhanqa kweShield ukuze kubhanqe ukumbozwa | 100% |
Isihlangu sangaphandle: | Umluko Wethusi Othintiwe Oqinile |
Ukufakwa kwesihlangu sangaphandle: | Nom 80% |
Ijakhethi yangaphandle: | I-LSZH SHF1 |
Ukujiya komgodla wangaphandle | 0.75 ± 0.30 mm |
Ijakhethi yangaphandle OD: | 8.4 ± 0.50 mm |
Ukumaka: | I-YANGER® CAT7 4x2x23/7 AWG Stranded S/FTP LSZH-SHF1 |
Umbala wejakhethi yangaphandle: | Okumpunga |
“Ubuqotho, Ukusungula, Ukuqina, kanye Nokuphumelela” kuwumbono oqhubekayo wenkampani yethu isikhathi eside ukuze yakhe ngokuhlanganyela nabathengi ukuze babuyisane futhi bathole umvuzo ofanayo we-Factory Outlets Siemens Lwl Sienopyr Marine Cable Fiber Optic Cable (yokubeka emikhunjini) kanye ne-Offshore Unit 30-601 I-Offshore Unit 30-001 Fiber Optic Cable wamukelekile abathengi abasekhaya nabaphesheya kwezilwandle ukuze basithinte futhi basebenzisane nathi ukuze ujabulele ikusasa elingcono.
Izitolo zasefekthriI-China Industrial Ethernet FC Tp Standard Cable ne-Standard Cable, Abasebenzi bethu babambelela emoyeni “wokusekela Ubuqotho kanye Nokuthuthukiswa Okusebenzisanayo”, kanye nemfundiso “Yekhwalithi Yezinga Lokuqala Ngesevisi Enhle Kakhulu”.Ngokwezidingo zawo wonke amakhasimende, sinikezela ngezinsizakalo ezenziwe ngezifiso nangokwezifiso ukuze sisize amakhasimende afinyelele izinjongo zawo ngempumelelo.Siyakwamukela amaklayenti asekhaya nakwamanye amazwe ukuze ushayele futhi ubuze!
Izinga le-acidity yamagesi: | I-IEC 60754-1/2 |
Igesi ye-Halogen acid: | I-IEC 60754-1/2 |
Ukukhishwa kwentuthu: | I-IEC 61034-1/2 |
I-flame retardant: | I-IEC 60332-1-2 |
Ukumelana ne-UV: | I-UL 1581 |
Isicishamlilo: | I-IEC 60332-3-22 |
Ukumelana ne-conductor@20°C: | ≤95.0 Ω/km |
Ukumelana ne-insulation: | ≥5000 MΩ/km |
Isilinganiso sesici esimaphakathi @100 MHz: | 100 ± 5 Ω |
I-impedance yokudlulisa: | ≤100 mΩ/m @10 MHz |
Libazisa i-skew (4~100 MHz): | ≤25 ns/100 m |
I-Velocity factor: | 74% |
Ukungalingani kwe-conductor phakathi kokubhanqwa: | ≤2.0% |
Ukungalingani kwe-conductor phakathi kwamapheya: | ≤4.0% |
amandla angalingani emhlabeni ku-800 Hz noma 1000 Hz: | ≤160 pF/100 m |
Amandla okusebenzisana: | ≤56 nF/km |
Imvamisa (MHz): | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 | 200 | 250 | 300 | 600 |
I-Attenuation dB/100m (Ubukhulu.) | - | 3.7 | 5.9 | 7.4 | 8.3 | 10.4 | 14.9 | 19 | 27.5 | 31 | 34.2 | 50.1 |
OKULANDELAYO dB (Min.) | 78 | 78 | 78 | 78 | 78 | 78 | 75.5 | 72.4 | 67.9 | 66.4 | 65.2 | 60.7 |
PS-NEXT (Min.) | 75 | 75 | 75 | 75 | 75 | 75 | 72.5 | 69.4 | 64.9 | 63.4 | 62.2 | 57.7 |
ELFEXT dB (Min.) | 78 | 78 | 75.3 | 71.2 | 69.3 | 65.4 | 59.4 | 55.3 | 49.3 | 47.3 | 45.8 | 38.4 |
I-Return Loss dB (Min.) | 20 | 23 | 25 | 25 | 25 | 23.6 | 21.5 | 20.1 | 18 | 17.3 | 17.3 | 17.3 |
I-PSELFEXT (Min.) | 75 | 75 | 72.3 | 68.2 | 66.3 | 62.4 | 56.4 | 52.3 | 46.3 | 44.3 | 42.8 | 35.4 |